Experimental and simulation studies were conducted to noninvasively characterize abdominal aneurysms with ultrasound (US) elastography before and after endovascular treatment. Twenty three dogs having bilateral aneurysms surgically created on iliac arteries with venous patches were investigated. In a first set of experiments, the feasibility of elastography to differentiate vascular wall elastic properties between the aneurismal neck (healthy region) and the venous patch (pathological region) was evaluated on six dogs. Lower strain values were found in venous patches (p < 0.001). In a second set of experiments, 17 dogs having endovascular repair (EVAR) by stent graft (SG) insertion were examined three months after SG implantation. Angiography, color Doppler US, examination of macroscopic sections and US elastography were used. The value of elastography was validated with the following end points by considering a solid thrombus of a healed aneurysm as a structure with small deformations and a soft thrombus associated with endoleaks as a more deformable tissue: (1) the correlation between the size of healed organized thrombi estimated by elastography and by macroscopic examinations; (2) the correlation between the strain amplitude measured within vessel wall elastograms and the leak size; and (3) agreement on the presence and size of endoleaks as determined by elastography and by combined reference imaging modalities (angiography + Doppler US). Mean surfaces of solid thrombi estimated with elastography were found correlated with those measured on macroscopic sections (r = 0.88, p < 0.001). Quantitative strain values measured within the vessel wall were poorly linked with the leak size (r = 0.12, p = 0.5). However, the qualitative evaluation of leak size in the aneurismal sac was very good, with a Kappa agreement coefficient of 0.79 between elastography and combined reference imaging modalities. In summary, complementing B-scan and color Doppler, noninvasive US elastography was found to be potentially a relevant tool for aneurismal follow-up after EVAR, provided it allows geometrical and mechanical characterizations of the solid thrombus within the aneurismal sac. This elasticity imaging technique might help detecting potential complications during follows-up subsequent to EVAR.
Physics in Medicine & Biology
Nov 3, 2008
Noninvasive vascular ultrasound elastography applied to the characterization of experimental aneurysms and follow-up after endovascular repair
J Fromageau et al 2008 Phys. Med. Biol. 53 6475-6490
About the author
Jérémie Fromageau, Sophie Lerouge, Roch Listz Maurice, Gilles Soulez and Guy Cloutier
(University of Montreal, Québec, Canada)