CHICAGO, IL, 3 November 2009 – Advocate Lutheran General Hospital in the Chicago suburb of Park Ridge has chosen ScandiDos as the provider of its quality assurance (QA) solution for RapidArc™, and, in doing so, becomes the 100th clinical installation of Delta4. In selecting the Delta4 volumetric QA system, cancer care physicists and physicians at Advocate Lutheran General Hospital now have access to cutting edge verification of radiation therapy treatment. Key to this is the capability to perform real dose measurements and analyze the dose in the isocentric target region, the volume of greatest concern. The Delta4. system is in clinical use for IMRT, Arc therapy and TomoTherapy® since 2006 at clinics around the world. As Advocate Lutheran General Hospital begins treating patients with RapidArc – one form of volumetric modulated arc therapy (VMAT) or intensity modulated arc therapy (IMAT), having Delta4. for the pretreatment measurement and analysis of treatment plans will provide clinicians the comfort and confidence to proceed with these new, advanced treatments. Delta4.’s unique, advanced approach to measuring and presenting the dose data in three dimensions allows for quick, easy, and precise analysis of the treatment in relation to the prescription dose to the patient. Delta4.’s sophisticated analysis software allows the medical physicist to quickly analyze the measured dose against the treatment plan to determine the significance and cause of deviations in the dose. Because VMAT/IMAT modalities such as RapidArc by Varian Medical Systems employ many more treatment angles than conventional intensity modulated radiation therapy (IMRT), an integral part of the analysis of such is the delivery of dose from each of the actual gantry angles that will be delivered to the patient and the independent verification of each gantry angle as an element of the dose analysis. Delta4. is the only volumetric QA system on the market to perform this independent gantry angle verification, and, as such, accounts for this area of potential discrepancy as part of its measurement. “We are very pleased that Advocate Lutheran General Hospital has chosen Delta4 PT as part of the technology solution to offer advanced radiation treatments to its patients”, says Brad Dugai, National Sales Manager at ScandiDos. “When we installed out first Delta4. in 2006, it was used to verify both IMRT and Arc Therapy treatments. Now, 3 years later, rotational therapy is becoming the new standard radiation therapy and, significantly, our 100th installed system will be used for both TomoTherapy and Varian RapidArc” says Ingemar Wiberg, VP of Sales and Marketing at ScandiDos. Delta4. has been used by linear accelerator manufacturers in the development and validation of arc therapy treatment modalities to include Varian’s RapidArc and Elekta’s VMAT solution.
Newsfeed
Nov 9, 2009