METZ, FRANCE, 10 March 2010 – Clinique Claude Bernard’s Private Radiotherapy Center of Metz (PRCM) uses Elekta’s definitive arc-based Volumetric Modulated Arc Therapy (VMAT) method to boost efficiency.
The quality and efficiency of arc-based radiation therapy has prompted PRCM (Metz, France) to use Elekta VMAT for nearly all cases. Eleven months after using VMAT on its first patient, PRCM has used the technique for more than 500 patients, half of which were prostate cancer cases. With Elekta VMAT, single or multiple radiation beams sweep in uninterrupted arc(s) around the patient, significantly reducing treatment times.
VMAT introduces efficiency into advanced radiation therapy method
To enhance the quality of its radiation treatments, PRCM began using Intensity Modulated Radiation Therapy (IMRT) for increasing numbers of patients. IMRT is an advanced radiotherapy method that enables doctors to conform more precisely to the 3D shape of the tumor – using radiation beams that vary in intensity and that come from different directions. While IMRT can create a treatment that maximizes dose to the target and minimizes dose to healthy tissues, it can lead to longer delivery times compared with standard radiation therapy, says Guillaume Faure, M.D., co-director of radiation oncology at PRCM, the first center in France to use Elekta VMAT.
Although integrating IMRT as our technique of choice increased treatment quality, treatment times increased, which led to an overall productivity decrease," he notes. "We realized that VMAT’s one to two, or more, non-stop beams would be more efficient than the standard IMRT delivery method, which requires five to seven beams and time-consuming data transfer between the treatment console and the linear accelerator for each beam."
PRCM acquired Elekta VMAT option in January 2009 and began treating the following month. Clinicians selected prostate cancer cases as the first Elekta VMAT cases due to their straightforward treatment requirements, but gradually added a wide range of cases, including head and neck, pelvis and metastases.
"Our radiation therapy technicians found learning Elekta VMAT to be extremely simple," Dr. Faure observes. "After only five months we were using VMAT to treat an average of 70 patients per day in an 11 to 12-hour day. At six months, almost everything apart from breast cancer cases was being done with the VMAT technique. Most importantly, the reduction in the length of treatment sessions is striking when compared to standard IMRT. VMAT treatment session times averaged half as long as those of IMRT."
A VMAT treatment session consists of pre-treatment image guidance time, patient set-up time and "beam-on time," – the latter is when radiation is applied to the target. Depending on several factors, pre-treatment image guidance and set-up times can lead to treatment sessions ranging from five to nine minutes. Therefore, PRCM adopted an average treatment session time of seven minutes for all cases. Because VMAT beam-on time for all indications measures in tens of seconds, it now contributes less significantly to the total treatment session time. At PRCM, average VMAT beam-on times for five major indications are:
• 102 seconds: Head-and-neck
• 98 seconds: Brain
• 81 seconds: Rectum
• 79 seconds: Prostate
• 79 seconds: Lung
The average VMAT beam-on time across these five case types is just 88 seconds.
Compared with total treatment session times for IMRT, an average VMAT treatment session (seven minutes) is typically twice as fast. Examples include prostate IMRT at 14 minutes; head and neck IMRT at 22 minutes and rectal IMRT at 11 minutes.
"The time-savings with VMAT is critical, because in addition to affording the patient a shorter time on the treatment table, it also frees up time to further adjust the patient’s treatment position using the treatment system’s integrated imaging technology," explains Dr. Faure.
PRCM performs a total of 215 treatments daily on its three Elekta Synergy® linear accelerators, for a total of 2,000 patients treated annually. It recently upgraded its two other Elekta Synergy: one dedicated for VMAT cases and the other for breast cases. The first breast VMAT cases are planned for March.
In the design of Elekta VMAT, Elekta has integrated the latest version of its digital control system, which facilitates clinical use of VMAT while emphasizing optimal patient safety.
About Elekta
Elekta is a human care company pioneering significant innovations and clinical solutions for treating cancer and brain disorders. The company develops sophisticated, state-of-the-art tools and treatment planning systems for radiation therapy and radiosurgery, as well as workflow enhancing software systems across the spectrum of cancer care.
Stretching the boundaries of science and technology, providing intelligent and resource-efficient solutions that offer confidence to both healthcare providers and patients, Elekta aims to improve, prolong and even save patient lives, making the future possible today.
Today, Elekta solutions in oncology and neurosurgery are used in over 5,000 hospitals globally, and every day more than 100,000 patients receive diagnosis, treatment or follow-up with the help of a solution from the Elekta Group.
Elekta employs around 2,500 employees globally. The corporate headquarter is located in Stockholm, Sweden, and the company is listed on the Nordic Exchange under the ticker EKTAb.