Skip to the content

IOP A community website from IOP Publishing

Company details

Imaging Equipment Ltd Sep 23, 2011

About this company

Imaging Equipment Ltd
The Barn, Manor Farm, Church Lane
Chilcompton, Radstock
Bath
BA3 4HP
BA3 4HP
United Kingdom

Tel: 01761-417402
Fax: 01761-413600

Imaging Equipment Ltd specialises in the supply of equipment for the modern health physics environment. We represent a wide range of international manufacturers.

 

Products from this company

  1. MapPHan enables rotational dosimetry Dec 10, 2008

    A homogenous water equivalent phantom is available for dosimetry of rotational radiotherapy beams.

  2. Specimen radiography system for biopsy inspection Jul 10, 2008

    The Kubtec Xpert 40 is a self-contained, shielded cabinet X-ray system.

  3. Developments in IMRT software Mar 31, 2008

    A well established reputation in IMRT QA, MapCHECK has two new members in the software family.

  4. Respisens tracks patient breathing Mar 20, 2008

    Targeting a lung/breast tumour while constantly moving due to respiration is not an easy task.

  5. Lemer Pax Posijet automates FDG infusion Mar 17, 2008

    Posijet calibrates by activity measurement, dilutes, and then injects a patient with a FDG solution.

  6. Mapcheck 2, the 'gold standard' for IMRT Mar 10, 2008

    MapCHECK2 is a real time absolute dose device.

  7. RadCalc reinforces verification Mar 3, 2008

    RAdcalc provides independent MU and point dose vertification calculations.

  8. Atlas provides a total system Jan 18, 2008

    Atlas is where the QA jigsaw pieces together to provide a total system for the recording, control and audit of all measureable functions within a treatment centre.

  9. Atom - dosimetry verification phantoms Jan 18, 2008

    ATOM phantoms are manufactured exclusively by CIRS. Standard phantoms include bone, lung and soft tissue compositions formulated for accurate simulation for diagnostic and therapy energies.

  10. Epidose converts EPID file to dose map Jan 16, 2008

    EPIDOSE is another license activated part of MapCHECK and one that will become increasingly more used and popular as the use of EPIDS increase.

  11. MapCalc verifies planning system outputs Jan 14, 2008

    Within the MAPCHECK software are other programs which can be activated with the purchased of additional licenses. One of these is MAPCALC.

  12. Daily QA3 offers daily quality assurance Jan 10, 2008

    Daily QA – Daily QA Accelerated ...an advanced tool for daily quality assurance of a radiation therapy beam

  13. RF-ivd enables in-vivo dosimetry Jan 8, 2008

    rf-IVD 2 and IVD 2 are four-channel measurement systems for in-vivo dosimetry – the real-time measurement of radiation dose administered to a patient during therapy.

  14. CR RadChex delivers wireless operation Jan 8, 2008

    The 07-CRXW Wireless CR RADCHEX is a factory, radiation-calibrated, and NIST-traceable light meter that can be used to calibrate (balance) CR plate readers (also radiation-calibrated light meters) in the field.

  15. MapCheck XY 4D for IGRT and IMRT QA Jan 4, 2008

    Map Check – The Gold Standard for IGRT & IMRT QA

  16. Profiler 2 offers water tank alternative Jan 4, 2008

    Profiler 2 uses 139 detectors which have the highest available sensitivity and lowest available volume of any Dosimetric measurement system.

  17. Dynamic phantom targets tumour motion Dec 21, 2007

    A dynamic thorax phantom for precise evaluation of lung tumor motion. The CIRS Dynamic Thorax Phantom is designed to investigate and minimize the impact of organ motion and patient positioning errors in radiation therapy.

  18. IC Profiler eases beam alignment Dec 20, 2007

    IC Profiler - Linac Servicing for the 21st Century. A LINAC radiation-beam scanning system providing real-time beam profile data for beam alignment during LINAC factory testing

  19. SunBeam radiosurgery saves time Dec 19, 2007

    SunBeam radiosurgery – redefining radiosurgery measurements. SunBeam tm is an all-in-one SRS beam QA tool designed to save time. CyberKnife users may attach SunBeam directly to the robot "birdcage" and measure any robot position.

  20. RadCalc targets treatment planning systems Dec 19, 2007

    RadCalc, independent MU and point dose verification calculations for both 3D and IMRT Treatment planning systems including MLC, Diode and VW/EDW