Data acquisition systems for multi-anode photomultiplier tubes, avalanche photodiode arrays, & silicon photomultipliers. Systems up to 64 channels for applications such as positron emission tomography (PET), SPECT, gamma cameras, & particle physics.
Categories
- Ionizing radiations (ultraviolet, X-rays,gamma-rays, ions, electrons, positrons, neutrons, and mesons, etc.)
- Single photon emission computed tomography (SPECT)
- Positron emission tomography (PET)
- Digital imaging
- Electron, neutron and X-ray diffraction and scattering
- Scattering of visible, uv, and infrared radiation
- Infrared and Raman spectroscopy
- Confocal microscopy
- Multiphoton microscopy
Products from this company
-
SIB416 Sensor Interface Board for Hamamatsu S11064 MPPC Nov 16, 2011
The SIB416 sensor interface board allows up to four Hamamatsu S11064 multi-pixel photon counter (MPPC) devices to easily interface to a Vertilon PhotoniQ multichannel data acquisition system.
-
SIB332 Sensor Interface Board for Hamamatsu S8550 32 Element APD Array Dec 15, 2010
The SIB332 sensor interface board provides the electrical and mechanical connectivity between a Hamamatsu S8550 4 x 8 element APD array and a Vertilon PhotoniQ multi-channel data acquisition system.
-
SIB1256 Sensor Interface Board for SensL SPMArray4 Dec 15, 2010
The SIB1256 sensor interface board allows up to four SensL SPMArray4 silicon photomultiplier arrays (SiPM) to easily interface to a Vertilon PhotoniQ multichannel data acquisition system.
-
MCPC618 Multichannel Photon Counting System Aug 9, 2010
The PhotoniQ model MCPC618 is a complete, off-the-shelf, high speed, eight channel photon counting system for PMTs, silicon photomultipliers (SiPM) and APDs.
-
PhotoniQ IQSP418 Expandable PMT Data Acquisition System Jan 19, 2010
The PhotoniQ IQSP418 is an economical multichannel data acquisition system designed to offer scientists and engineers an off-the-shelf solution for data collection from multiple charge-based sensors.
-
SIB232 PMT Sensor Interface Board H7260 Series Nov 9, 2009
The SIB232 PMT Sensor Interface Board provides the connectivity between a Hamamatsu H7260 series linear 32 channel photomultiplier tube and a Vertilon PhotoniQ multi-channel data acquisition system.
-
SIB2316 Sensor Interface Board for SensL SPMArray May 11, 2009
The SIB2316 silicon photomultiplier interface board provides the connectivity between two SensL SPMArrays & external signal processing electronics such as a Vertilon PhotoniQ data acquisition system.
-
SIB016 Sensor Interface Board for Hamamatsu R5900U-L16 PMT May 8, 2009
With applications in positron emission tomography (PET) & SPECT, the SIB016 provides the electrical & mechanical connectivity between a Hamamatsu R5900U 16 channel PMT & multi-channel DAQ systems.
-
IQSP482 64 channel photomultiplier tube data acquisition system Sep 19, 2008
Sixty-Four Channel Data Acquisition System for Photomultiplier Tubes, Silicon Photomultipliers & Avalanche Photodiode Arrays.
-
IQSP582 data acquisition system for PET and SPECT Sep 19, 2008
Sixty-four channel data acquisition product used with Hamamatsu H7546B & H8500D Multianode PMTs, silicon photomultipliers, & avalanche photodiode arrays.
-
Sensor interface board for Hamamatsu H7546B Jul 17, 2008
Provides connectivity between the Hamamatsu H7546B PMT and multichannel data acquisition systems.
-
Sensor interface board for multianode PMT Apr 30, 2008
Provides connectivity between the Hamamatsu H8500D PMT and multichannel data acquisition systems.
-
Interface board provides PMT connection Mar 17, 2008
The SIB116 provides the interface between a Hamamatsu H8711 MAPMT & multichannel DAQ systems.
-
Data acquisition system eyes PET Oct 22, 2007
Thirty-two-channel data-acquisition system for multianode photomultiplier tubes (MAPMT) and avalanche-photodiode arrays.