3D Dosimetry

3D Dosimetry as a Service

3D Dosimetry as a Service
3DDaaS is a remote readout 3D Dosimetry service designed for radiotherapy QA. This service makes use of ClearView™ 3D Gel Dosimeters and is now being tested in clinical trials. ClearView™ gels are delivered to your clinic for you to irradiate and then send back to Modus QA along with your treatment plan. Modus QA scans your gel and prepares your data for analysis. The results are returned to you with VistaView™ software for visualization and comparison of the results.

Learn more

ClearView™ 3D Gel Dosimeter

ClearView™ 3D Gel Dosimeter
ClearView™ is a single-use radiochromic 3D gel dosimeter designed for remote or on-site read-out by Optical CT. Applications for this 3D dosimeter include SRS, SBRT, VMAT and IMRT. ClearView™ is stable in storage for over 90 days and the signal is stable for more than a week after irradiation. It is made with low scatter gel that works well with the Vista™ Optical CT Scanner as well as laser optical CT scanners.

Learn more

Vista™  Optical CT Scanner

Vista™ Optical CT Scanner
Vista™ is a fast cone beam optical CT scanner designed for True 3D Dosimetry. Vista™ is used for on-site or remote scanning of 3D dosimeters including ClearView™ and TruView™. The Vista™ Optical CT Scanner includes software for acquisition, reconstruction, and display of 3D optical CT images. Images from Vista™ are analyzed in VistaView™ software as well as a variety of 3rd party software applications.

Learn more

Vista™  Optical CT Scanner

TruView™ 3D Gel Dosimeter
TruView™ is a multi-use radiochromic 3D gel dosimeter designed for on-site read-out by Optical CT. Applications for this 3D dosimeter include IMRT, VMAT, SRS and SBRT. TruView™ is stable in storage for up to 30 days. The signal must be read out between 45 and 90 minutes after irradiation which requires an optical CT scanner on-site. TruView™ can be used again 48 hours after irradiation. It is made with low scatter gel that works well with the Vista™ Optical CT Scanner as well as fast laser optical CT scanners.

Learn more